Ports
6 Redundant power supply ports
Restrictions: Each port can provide redundant +12V power to a connected switch; only one port can provide power at a given time
2 External power supply ports
Restrictions: Provides +50 Vdc external PoE power to up to two switch devices. Provides max of 408W at full power to one device, and half power (204W each) if connected to two devices.
Physical characteristics
Dimensions: 12.83 x 17.44 x 1.73 in. (32.6 x 44.3 x 4.4 cm) (1U height)
Weight: 11.78 lb (5.3 kg) fully loaded
Cabling
- Included are six(6) RPS cables and two(2) EPS cables
- RPS cables (part # 5069-5729) are 1.25 meters (4.10 feet) in length
- EPS cables (part # 5069-5718)are 2.00 meters (6.56 feet) in length
Mounting
1U rack-mountable and wall-mountable enclosure using standard mounting hardware
Environment
Operating
– Temperature: 32 ºF to 131 ºF (0 ºC to 55 ºC)
– Relative Humidity: 15 % to 95 % at 104 ºF (40 ºC), noncondensing
Non-operating/Storage
– Temperature: -40 ºF to 158 ºF (-40 ºC to 70 ºC)
Altitude: up to 15,091 ft (4.6 km)
Acoustic: Noise emission LwA=59.2 dB at virtual workspace according to DIN 45635 T.19
Electrical characteristics
The unit automatically adjusts to any voltage between 100-240 V and either 50 or 60 Hz
Voltage: 100-240 VAC
Current: 9 A /5 A
RPS Power: 204W
PoE Power: 821W
Frequency: 50/60 Hz
Safety
CSA 22.2 No. 60950; EN 60950/IEC 60950; UL 60950
Emissions
FCC Class A; FCC Part 15.107;CISPR-22; VCCI;ICES-003 (Canada)
Immunity
Generic: CISPR-24
Management
Unmanaged power supply - provides information via LEDs or through port interfaces of attached devices
Supported Devices
ProCurve Switch 2600 Series
ProCurve Switch 2800 Series
ProCurve Switch 5300xl Series
ProCurve Switch 3400cl Series |
|