document.write('<div><table cellpadding="0" cellspacing="0" border="0" summary="layout"><tr><td valign="top"><ul class="linksUnit"><li class="bold">&raquo;<a href="#differences">Model differences</a></li><li>&raquo;<a href="#ports">Ports</a></li><li>&raquo;<a href="#powerSup">Power supplies</a></li><li>&raquo;<a href="#physChar">Physical characteristics</a></li><li>&raquo;<a href="#memory">Memory and processor</a></li><li>&raquo;<a href="#mount">Mounting</a></li><li>&raquo;<a href="#perf">Performance</a></li><li>&raquo;<a href="#env">Environment</a></li><li>&raquo;<a href="#elecChar">Electrical characteristics</a></li><li>&raquo;<a href="#safety">Safety</a></li><li>&raquo;<a href="#notes">Notes</a></li></ul></td><td valign="top"><img src="http://welcome.hp-ww.com/img/s.gif" width="20" height="0" alt="" /></td><td valign="top"><ul class="linksUnit"><li class="bold">&raquo;<a href="#models">Standard specifications across all models</a></li><li>&raquo;<a href="#emission">Emissions</a></li><li>&raquo;<a href="#immunity">Immunity</a></li><li>&raquo;<a href="#management">Management</a></li><li>&raquo;<a href="#stadProc">Standards and protocols</a></li></ul></td></tr></table></div><div class="topSpace"><h3 class="headerBetaBevel"><a name="differences"></a>Model differences</h3></div><div><table width="100%" bgcolor="#cccccc" border="0" cellpadding="4" cellspacing="1"><tr class="theme"><th align="left" valign="top" class="small themebody"></th><th align="left" valign="top" scope="col" class="small themebody">HP ProCurve 2910al-24G Switch<br />(J9145A)</th><th align="left" valign="top" scope="col" class="small themebody">HP ProCurve 2910al-48G Switch<br />(J9147A)</th><th align="left" valign="top" scope="col" class="small themebody">HP ProCurve 2910al-24G-PoE+ Switch<br />(J9146A)</th></tr><tr valign="top" bgcolor="#666666"><td class="small bold colorFFFFFF" scope="col" colspan="4"><a name="ports"></a>Ports</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row"></td><td class="small">20 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)<br /><br />Media Type: Auto-MDIX<br /><br />Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only<br /><br />4 dual-personality ports<br /><br />each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or as a mini-GBIC slot (for use with mini-GBIC transceivers)<br /><br />1 RJ-45 serial console port<br /><br />Supports a maximum of 4 10-GbE ports, with optional module<br /><br /></td><td class="small">44 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)<br /><br />Media Type: Auto-MDIX<br /><br />Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only<br /><br />4 dual-personality ports<br /><br />each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or as a mini-GBIC slot (for use with mini-GBIC transceivers)<br /><br />1 RJ-45 serial console port<br /><br />Supports a maximum of 4 10-GbE ports, with optional module<br /><br /></td><td class="small">20 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)<br /><br />Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only<br /><br />4 dual-personality ports<br /><br />each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or as a mini-GBIC slot (for use with mini-GBIC transceivers<br /><br />1 RJ-45 serial console port<br /><br />Supports a maximum of 4 10-GbE ports, with optional module<br /><br /></td></tr><tr valign="top" bgcolor="#666666"><td class="small bold colorFFFFFF" scope="col" colspan="4"><a name="physChar"></a>Physical characteristics</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row">Dimensions</td><td class="small">14.4(d) x 17.4(w) x 1.73(h) in. (36.58 x 44.2 x 4.4 cm) (1U height)</td><td class="small">14.4(d) x 17.42(w) x 1.73(h) in. (36.58 x 44.25 x 4.4 cm) (1U height)</td><td class="small">14.4(d) x 17.4(w) x 1.73(h) in. (36.58 x 44.2 x 4.39 cm) (1U height)</td></tr><tr valign="top" bgcolor="#ffffff"><td class="small bold" scope="row">Weight</td><td class="small">10.92 lb. (4.95 kg)</td><td class="small">11.2 lb. (5.08 kg)</td><td class="small">12.34 lb. (5.6 kg)</td></tr><tr valign="top" bgcolor="#666666"><td class="small bold colorFFFFFF" scope="col" colspan="4"><a name="memory"></a>Memory and processor</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row">Processor</td><td class="small">Dual ARM1156T2S @ 515 MHz, 4 MB flash, 1 GB flash ROM, 512 MB SDRAM; packet buffer size: 6 MB</td><td class="small">Dual ARM1156T2S @ 515 MHz, 4 MB flash, 1 GB flash ROM, 512 MB SDRAM; packet buffer size: 6 MB</td><td class="small">Dual ARM1156T2S @ 515 MHz, 4 MB flash ROM, 1 GB flash, 512 MB SDRAM; packet buffer size: 6 MB</td></tr><tr valign="top" bgcolor="#666666"><td class="small bold colorFFFFFF" scope="col" colspan="4"><a name="mount"></a>Mounting</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row"></td><td class="small">Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only.<br /></td><td class="small">Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only.<br /></td><td class="small">Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only<br /></td></tr><tr valign="top" bgcolor="#666666"><td class="small bold colorFFFFFF" scope="col" colspan="4"><a name="perf"></a>Performance</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row">1000 Mb Latency</td><td class="small">&lt; 2.9 &#181;s (FIFO 64-byte packets)</td><td class="small">&lt; 2.9 &#181;s (FIFO 64-byte packets)</td><td class="small">&lt; 2.9 &#181;s (FIFO)</td></tr><tr valign="top" bgcolor="#ffffff"><td class="small bold" scope="row">10 Gbps Latency</td><td class="small">&lt; 1.3 &#181;s (FIFO 64-byte packets)</td><td class="small">&lt; 1.3 &#181;s (FIFO 64-byte packets)</td><td class="small">&lt; 1.3 &#181;s (FIFO)</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row">Throughput</td><td class="small">up to 95 million pps (64-byte packets)</td><td class="small">up to 131 million pps</td><td class="small">up to 95 million pps</td></tr><tr valign="top" bgcolor="#ffffff"><td class="small bold" scope="row">Switching capacity</td><td class="small">128 Gbps</td><td class="small">176 Gbps</td><td class="small">128 Gbps</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row">Routing table size</td><td class="small">2,000 entries</td><td class="small">2,000 entries</td><td class="small">2,000 entries</td></tr><tr valign="top" bgcolor="#ffffff"><td class="small bold" scope="row">MAC address table size</td><td class="small">16,000 entries</td><td class="small">16,000 entries</td><td class="small">16,000 entries</td></tr><tr valign="top" bgcolor="#666666"><td class="small bold colorFFFFFF" scope="col" colspan="4"><a name="env"></a>Environment</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row">Operating temperature</td><td class="small">32ºF to 131ºF (0ºC to 55ºC)</td><td class="small">32ºF to 122ºF (0ºC to 50ºC)</td><td class="small">32ºF to 131ºF (0ºC to 55ºC)</td></tr><tr valign="top" bgcolor="#ffffff"><td class="small bold" scope="row">Operating relative humidity</td><td class="small">15% to 95% @ 104ºF (40ºC), non-condensing</td><td class="small">15% to 95% @ 104ºF (40ºC), non-condensing</td><td class="small">15% to 95% @ 104ºF (40ºC), non-condensing</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row">Non-operating/Storage temperature</td><td class="small">-40ºF to 158ºF (-40ºC to 70ºC)</td><td class="small">-40ºF to 131ºF (-40ºC to 55ºC)</td><td class="small">-40ºF to 158ºF (-40ºC to 70ºC)</td></tr><tr valign="top" bgcolor="#ffffff"><td class="small bold" scope="row">Non-operating/Storage relative humidity</td><td class="small">15% to 95% @ 149ºF (65ºC), non-condensing</td><td class="small">15% to 95% @ 149ºF (65ºC), non-condensing</td><td class="small">15% to 95% @ 149ºF (65ºC), non-condensing</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row">Altitude</td><td class="small">up to 10,000 ft. (3 km)</td><td class="small">up to 10,000 ft. (3 km)</td><td class="small">up to 10,000 ft. (3 km)</td></tr><tr valign="top" bgcolor="#ffffff"><td class="small bold" scope="row">Acoustic</td><td class="small">Power: 53.5 dB, Pressure: 39.4 dB; DIN 45635T.19 per ISO 7779</td><td class="small">Power: 53.5 dB, Pressure: 39.4 dB; DIN 45635T.19 per ISO 7779</td><td class="small">Power: 51.5 dB, Pressure: 38.1 dB; DIN 45635T.19 per ISO 7779</td></tr><tr valign="top" bgcolor="#666666"><td class="small bold colorFFFFFF" scope="col" colspan="4"><a name="elecChar"></a>Electrical characteristics</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row">Description</td><td class="small">The switch automatically adjusts to any voltage between 100-127 and 200-240 volts and either 50 or 60 Hz</td><td class="small">The switch automatically adjusts to any voltage between 100-127 and 200-240 volts and either 50 or 60 Hz</td><td class="small">The switch automatically adjusts to any voltage between 100-127 and 200-240 volts and either 50 or 60 Hz</td></tr><tr valign="top" bgcolor="#ffffff"><td class="small bold" scope="row">Maximum heat dissipation</td><td class="small">279 BTU/hr (295 kJ/hr)</td><td class="small">356 BTU/hr (376 kJ/hr)</td><td class="small">447 BTU/hr (472  kJ/hr), max. using PoE+</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row">Voltage</td><td class="small">100-127 / 200-240 VAC</td><td class="small">100-127 / 200-240 VAC</td><td class="small">100-127 / 200-240 VAC</td></tr><tr valign="top" bgcolor="#ffffff"><td class="small bold" scope="row">Current</td><td class="small">1.7 / 0.9 A</td><td class="small">2.1 / 1.1 A</td><td class="small">6.1 / 3.1 A</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row">Idle power</td><td class="small">49 W</td><td class="small">64 W</td><td class="small">65 W</td></tr><tr valign="top" bgcolor="#ffffff"><td class="small bold" scope="row">Power consumption</td><td class="small">82 W</td><td class="small">105 W</td><td class="small">490 W</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row">Frequency</td><td class="small">50 / 60 Hz</td><td class="small">50 / 60 Hz</td><td class="small">50 / 60 Hz</td></tr><tr valign="top" bgcolor="#ffffff"><td class="small bold" scope="row">Notes</td><td class="small">Idle power is the power consumption of the base system with no traffic.</td><td class="small">Idle power is the power consumption of the base system with no traffic.</td><td class="small">Idle power is the power consumption of the base system with no traffic.</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row"></td><td class="small">Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.</td><td class="small">Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.</td><td class="small">Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.</td></tr><tr valign="top" bgcolor="#666666"><td class="small bold colorFFFFFF" scope="col" colspan="4"><a name="safety"></a>Safety</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row"></td><td class="small">EN 60950/IEC 60950<br />CAN/CSA 22.2 No. 60950<br />EN 60825<br />UL 60950<br /></td><td class="small">EN 60950/IEC 60950<br />CAN/CSA 22.2 No. 60950<br />EN 60825<br />UL 60950<br /></td><td class="small">EN 60950/IEC 60950<br />CAN/CSA 22.2 No. 60950<br />EN 60825<br />UL 60950<br /></td></tr><tr valign="top" bgcolor="#666666"><td class="small bold colorFFFFFF" scope="col" colspan="4"><a name="notes"></a>Notes</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row"></td><td class="small">When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required.<br /><br /></td><td class="small">When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required.<br /><br /></td><td class="small">When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required.<br /><br /></td></tr></table></div><div class="topSpace"><ul class="linksUnit" style="text-align: right;"><li>&raquo;<a href="#tabs">Return to top</a></li></ul></div><div class="topSpace"><table width="100%" bgcolor="#cccccc" border="0" cellpadding="4" cellspacing="1"><tr class="theme"><th align="left" valign="top" class="small themebody"></th><th align="left" valign="top" scope="col" class="small themebody">HP ProCurve 2910al-48G-PoE+ Switch<br />(J9148A)</th></tr><tr valign="top" bgcolor="#666666"><td class="small bold colorFFFFFF" scope="col" colspan="5">Ports</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row"></td><td class="small">44 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)<br /><br />Media Type: Auto-MDIX<br /><br />Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only<br /><br />4 dual-personality ports<br /><br />each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or as a mini-GBIC slot (for use with mini-GBIC transceivers)<br /><br />1 RJ-45 serial console port<br /><br />Supports a maximum of 4 10-GbE ports, with optional module<br /><br /></td></tr><tr valign="top" bgcolor="#666666"><td class="small bold colorFFFFFF" scope="col" colspan="5">Physical characteristics</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row">Dimensions</td><td class="small">14.4(d) x 17.42(w) x 1.73(h) in. (36.58 x 44.25 x 4.39 cm) (1U height)</td></tr><tr valign="top" bgcolor="#ffffff"><td class="small bold" scope="row">Weight</td><td class="small">12.96 lb. (5.88 kg)</td></tr><tr valign="top" bgcolor="#666666"><td class="small bold colorFFFFFF" scope="col" colspan="5">Memory and processor</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row">Processor</td><td class="small">Dual ARM1156T2S @ 515 MHz, 4 MB flash ROM, 1 GB flash, 512 MB SDRAM; packet buffer size: 6 MB</td></tr><tr valign="top" bgcolor="#666666"><td class="small bold colorFFFFFF" scope="col" colspan="5">Mounting</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row"></td><td class="small">Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only<br /></td></tr><tr valign="top" bgcolor="#666666"><td class="small bold colorFFFFFF" scope="col" colspan="5">Performance</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row">1000 Mb Latency</td><td class="small">&lt; 2.9 &#181;s (FIFO)</td></tr><tr valign="top" bgcolor="#ffffff"><td class="small bold" scope="row">10 Gbps Latency</td><td class="small">&lt; 1.3 &#181;s (FIFO)</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row">Throughput</td><td class="small">up to 131 million pps</td></tr><tr valign="top" bgcolor="#ffffff"><td class="small bold" scope="row">Switching capacity</td><td class="small">176 Gbps</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row">Routing table size</td><td class="small">2,000 entries</td></tr><tr valign="top" bgcolor="#ffffff"><td class="small bold" scope="row">MAC address table size</td><td class="small">16,000 entries</td></tr><tr valign="top" bgcolor="#666666"><td class="small bold colorFFFFFF" scope="col" colspan="5">Environment</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row">Operating temperature</td><td class="small">32ºF to 131ºF (0ºC to 55ºC)</td></tr><tr valign="top" bgcolor="#ffffff"><td class="small bold" scope="row">Operating relative humidity</td><td class="small">15% to 95% @ 104ºF (40ºC), non-condensing</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row">Non-operating/Storage temperature</td><td class="small">-40ºF to 158ºF (-40ºC to 70ºC)</td></tr><tr valign="top" bgcolor="#ffffff"><td class="small bold" scope="row">Non-operating/Storage relative humidity</td><td class="small">15% to 95% @ 149ºF (65ºC), non-condensing</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row">Altitude</td><td class="small">up to 10,000 ft. (3 km)</td></tr><tr valign="top" bgcolor="#ffffff"><td class="small bold" scope="row">Acoustic</td><td class="small">Power: 51.5 dB, Pressure: 38.1 dB; DIN 45635T.19 per ISO 7779</td></tr><tr valign="top" bgcolor="#666666"><td class="small bold colorFFFFFF" scope="col" colspan="5">Electrical characteristics</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row">Description</td><td class="small">The switch automatically adjusts to any voltage between 100-127 and 200-240 volts and either 50 or 60 Hz</td></tr><tr valign="top" bgcolor="#ffffff"><td class="small bold" scope="row">Maximum heat dissipation</td><td class="small">667 BTU/hr (704  kJ/hr), max. uisng PoE+</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row">Voltage</td><td class="small">100-127 / 200-240 VAC</td></tr><tr valign="top" bgcolor="#ffffff"><td class="small bold" scope="row">Current</td><td class="small">6.4 / 3.2 A</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row">Idle power</td><td class="small">89 W</td></tr><tr valign="top" bgcolor="#ffffff"><td class="small bold" scope="row">Power consumption</td><td class="small">556 W</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row">Frequency</td><td class="small">50 / 60 Hz</td></tr><tr valign="top" bgcolor="#ffffff"><td class="small bold" scope="row">Notes</td><td class="small">Idle power is the power consumption of the base system with no traffic.</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row"></td><td class="small">Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.</td></tr><tr valign="top" bgcolor="#666666"><td class="small bold colorFFFFFF" scope="col" colspan="5">Safety</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row"></td><td class="small">EN 60950/IEC 60950<br />CAN/CSA 22.2 No. 60950<br />EN 60825<br />UL 60950<br /></td></tr><tr valign="top" bgcolor="#666666"><td class="small bold colorFFFFFF" scope="col" colspan="5">Notes</td></tr><tr valign="top" bgcolor="#e7e7e7"><td class="small bold" scope="row"></td><td class="small">When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required.<br /><br /></td></tr></table></div><div class="topSpace"><ul class="linksUnit" style="text-align: right;"><li>&raquo;<a href="#tabs">Return to top</a></li></ul></div><div class="topSpace"><h3 class="headerBetaBevel"><a name="models"></a>Standard specifications across all models</h3></div><div><h4 class="headerGamma"><a name="emission"></a>Emissions</h4>FCC part 15 Class A; EN 55022/CISPR-22 Class A; VCCI Class A</div><div class="topSpace"><h4 class="headerGamma"><a name="immunity"></a>Immunity</h4>EN: EN 55024, CISPR 24<br /><br />ESD: IEC 61000-4-2; 4 kV CD, 8 kV AD<br /><br />Radiated: IEC 61000-4-3; 3 V/m<br /><br />EFT/Burst: IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)<br /><br />Surge: IEC 61000-4-5; 1 kV / 2 kV AC, 1 kV signal, 0.5 kV DC<br /><br />Conducted: IEC 61000-4-6; 3 V<br /><br />Power frequency magnetic field: IEC 61000-4-8; 1 A/m<br /><br />Voltage dips and interruptions: IEC 61000-4-11; > 95% reductions, 0.5 period; 30% reduction, 25 periods<br /><br />Harmonics: IEC 61000-3-2<br /><br />Flicker: IEC 61000-3-3</div><div class="topSpace"><h4 class="headerGamma"><a name="management"></a>Management</h4>HP ProCurve Manager Plus; HP ProCurve Manager; command-line interface; Web browser; out-of-band management (serial RS-232C)</div><div class="topSpace"><h4 class="headerGamma"><a name="stadProc"></a>Standards and protocols</h4><table cellpadding="0" cellspacing="0" border="0" summary="layout"><tr><td valign="top"><h4 class="bold" style="margin-bottom: 0px;">Device management</h4>RFC 1591 DNS (client)<br />HTML and telnet management<br /><br /><h4 class="bold" style="margin-bottom: 0px;">General protocols</h4>IEEE 802.1D MAC Bridges<br />IEEE 802.1p Priority<br />IEEE 802.1Q VLANs<br />IEEE 802.1s Multiple Spanning Trees<br />IEEE 802.1v VLAN classification by Protocol and Port<br />IEEE 802.1w Rapid Reconfiguration of Spanning Tree<br />IEEE 802.3ad Link Aggregation Control Protocol (LACP)<br />IEEE 802.3x Flow Control<br />RFC 768 UDP<br />RFC 783 TFTP Protocol (revision 2)<br />RFC 792 ICMP<br />RFC 793 TCP<br />RFC 826 ARP<br />RFC 854 TELNET<br />RFC 868 Time Protocol<br />RFC 951 BOOTP<br />RFC 1058 RIPv1<br />RFC 1350 TFTP Protocol (revision 2)<br />RFC 2030 Simple Network Time Protocol (SNTP) v4<br />RFC 2131 DHCP<br />RFC 2453 RIPv2<br />RFC 3046 DHCP Relay Agent Information Option<br /><br /><h4 class="bold" style="margin-bottom: 0px;">IP multicast</h4>RFC 3376 IGMPv3 (host joins only)<br /><br /><h4 class="bold" style="margin-bottom: 0px;">IPv6</h4>RFC 1981 IPv6 Path MTU Discovery<br />RFC 2460 IPv6 Specification<br />RFC 2710 Multicast Listener Discovery (MLD) for IPv6<br />RFC 2925 Remote Operations MIB (Ping only)<br />RFC 3019 MLDv1 MIB<br />RFC 3315 DHCPv6 (client only)<br />RFC 3513 IPv6 Addressing Architecture<br />RFC 3596 DNS Extension for IPv6<br />RFC 3810 MLDv2 (host joins only)<br />RFC 4022 MIB for TCP<br />RFC 4113 MIB for UDP<br />RFC 4251 SSHv6 Architecture</td><td valign="top"><img src="http://welcome.hp-ww.com/img/s.gif" width="20" height="0" alt="" /></td><td valign="top">RFC 4252 SSHv6 Authentication<br />RFC 4253 SSHv6 Transport Layer<br />RFC 4254 SSHv6 Connection<br />RFC 4293 MIB for IP<br />RFC 4419 Key Exchange for SSH<br />RFC 4443 ICMPv6<br />RFC 4541 IGMP &amp; MLD Snooping Switch<br />RFC 4861 IPv6 Neighbor Discovery<br />RFC 4862 IPv6 Stateless Address Auto-configuration<br /><br /><h4 class="bold" style="margin-bottom: 0px;">MIBs</h4>RFC 1213 MIB II<br />RFC 1493 Bridge MIB<br />RFC 1724 RIPv2 MIB<br />RFC 2021 RMONv2 MIB<br />RFC 2613 SMON MIB<br />RFC 2618 RADIUS Client MIB<br />RFC 2620 RADIUS Accounting MIB<br />RFC 2665 Ethernet-Like-MIB<br />RFC 2668 802.3 MAU MIB<br />RFC 2674 802.1p and IEEE 802.1Q Bridge MIB<br />RFC 2737 Entity MIB (Version 2)<br />RFC 2863 The Interfaces Group MIB<br /><br /><h4 class="bold" style="margin-bottom: 0px;">Network management</h4>IEEE 802.1AB Link Layer Discovery Protocol (LLDP)<br />RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events)<br />RFC 3176 sFlow<br />ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)<br />SNMPv1/v2c/v3<br />XRMON<br /><br /><h4 class="bold" style="margin-bottom: 0px;">QoS/Cos</h4>RFC 2474 DiffServ Precedence, including 8 queues/port<br />RFC 2597 DiffServ Assured Forwarding (AF)<br />RFC 2598 DiffServ Expedited Forwarding (EF)<br />Ingress Rate Limiting<br /><br /><h4 class="bold" style="margin-bottom: 0px;">Security</h4>IEEE 802.1X Port Based Network Access Control<br />RFC 1492 TACACS+<br />RFC 2138 RADIUS Authentication<br />RFC 2866 RADIUS Accounting<br />Secure Sockets Layer (SSL)</td></tr></table></div><div class="topSpace"><ul class="linksUnit" style="text-align: right;"><li>&raquo;<a href="#tabs">Return to top</a></li></ul></div>');