| HP part number |
ProCurve Switch 5308xl
(J4819A) |
ProCurve Switch 5372xl
(J4848B) |
ProCurve Switch 5348xl
(J4849A) |
| Included Accessories |
|
3 ProCurve Switch xl 10/100-TX Module(J4820B)
|
2 ProCurve Switch xl 10/100-TX Module(J4820B)
|
| Ports |
8 open module slots
Supports a maximum 192 10/100 ports or 128 10/100/1000 ports.
|
5 open module slots
72 RJ-45 10/100 ports
Supports a maximum of 192 10/100 ports or 128 10/100/1000 ports.
|
2 open module slots
48 RJ-45 10/100 ports
Supports a maximum of 96 10/100 ports or 64 10/100/1000 ports.
|
| Physical characteristics |
|
|
|
| Dimensions: |
17.4 x 15.3 x 8.75 in.
(44.2 x 38.86 x 22.23 cm)
5U height |
17.4 x 15.3 x 8.75 in.
(44.2 x 38.86 x 22.23 cm)
5U height |
17.4 x 15.3 x 5.25 in.
(44.2 x 38.86 x 13.34 cm)
3U height |
| Weight: |
26.65 lb (11.99 kg)
fully loaded |
31.05 lb (14.08 kg)
fully loaded |
24.65 lb (11.09 kg)
fully loaded |
| Memory and processor |
|
|
|
| Fabric module: |
Motorola PowerPC @ 200 MHz, 12 MB flash, 32 MB SDRAM |
Motorola PowerPC @ 200 MHz, 12 MB flash, 32 MB SDRAM |
Motorola PowerPC @ 200 MHz, 12 MB flash, 32 MB SDRAM |
| Module: |
|
ARM7 @ 66 MHz, 128 KB flash, 128 KB SRAM, 18 MB RDRAM Packet buffer size: 36 MB |
ARM7 @ 66 MHz, 128 KB flash, 128 KB SRAM, 18 MB RDRAM Packet buffer size: 36 MB |
| Flash: |
Dual Flash |
Dual Flash |
Dual Flash |
| Packet buffer size: |
36 MB |
|
|
| Performance |
|
|
|
| Latency: |
< 6 µs (FIFO) |
< 6 µs (FIFO) |
< 6 µs (FIFO) |
| Throughput: |
up to 48 million pps |
up to 48 million pps |
up to 24 million pps |
| Switch fabric speed: |
76.8 Gbps |
76.8 Gbps |
38.4 Gbps |
| Address table size: |
10,000 entries |
10,000 entries |
10,000 entries |
| Environment |
|
|
|
| Operating temperature: |
32 °F to 104 °F (0 °C to 40 °C) |
32 °F to 104 °F (0 °C to 40 °C) |
32 °F to 104 °F (0 °C to 40 °C) |
| Operating relative humidity: |
15 % to 95 % at 104 °F (40 °C), noncondensing |
15 % to 95 % at 104 °F (40 °C), noncondensing |
15 % to 95 % at 104 °F (40 °C), noncondensing |
| Non-operating/storage temperature: |
-40 °F to 158 °F (-40 °C to 70 °C) |
-40 °F to 158 °F (-40 °C to 70 °C) |
-40 °F to 158 °F (-40 °C to 70 °C) |
| Non-operating/storage relative humidty: |
15 % to 95 % at 149 °F (65 °C), noncondensing |
15 % to 95 % at 149 °F (65 °C), noncondensing |
15 % to 95 % at 149 °F (65 °C) |
| Altitude: |
up to 15,091 ft (4.6 km) |
up to 15,091 ft (4.6 km) |
up to 15,091 ft (4.6 km) |
| Electrical characteristics |
|
|
|
| Maximum BTUs: |
2,152 BTU/hr |
2,152 BTU/hr |
2,152 BTU/hr |
| Voltage: |
100-127 VAC/200-240 VAC |
100-127 VAC/200-240 VAC |
100-127 VAC/200-240 VAC |
| Current: |
8.2 A /3.8 A |
8.2 A /3.8 A |
8.2 A /3.8 A |
| Power: |
630 W |
630 W |
630 W |
| Frequency: |
50/60 Hz |
50/60 Hz |
50/60 Hz |
|
|
» Return to top
|
| HP part number |
ProCurve Switch 5304xl
(J4850A) |
ProCurve Switch 5304xl-32G
(J8166A) |
ProCurve Switch 5308xl-48G
(J8167A) |
| Included Accessories |
|
2 ProCurve Switch xl 16-port 10/100/1000 Module(J4907A)
|
3 ProCurve Switch xl 16-port 10/100/1000 Module(J4907A)
|
| Ports |
4 open module slots
Supports a maximum of , 64 10/100/1000 , 96 10/100 ports, or a combination
|
2 open module slots
4 X2 ports
32 10GbE open transceiver slots
Supports a maximum of 96 10/100 ports or 56
10/100/1000 ports.
8 Dual Personality Ports can use either
the 10/100/1000 Gigabit RJ-45 port for UTP cabling
or the mini-GBIC port with mini-GBIC transceivers
|
5 open module slots
6 X2 ports
48 10GbE open transceiver slots
Supports a maximum of 192 10/100 ports or
112 10/100/1000 ports.
16 Dual Personality Ports can use
either the 10/100/1000 Gigabit RJ-45 port for UTP
cabling or the mini-GBIC port with mini-GBIC
transceivers
|
| Physical characteristics |
|
|
|
| Dimensions: |
17.4 x 15.3 x 5.25 in.
(44.2 x 38.86 x 13.34 cm)
3U height |
17.4 x 15.3 x 5.25 in.
(44.2 x 38.86 x 13.34 cm)
3U height |
17.4 x 15.3 x 8.75 in.
(44.2 x 38.86 x 22.23 cm)
5U height |
| Weight: |
21.71 lb (9.77 kg)
fully loaded |
24.25 lb (10.91 kg)
fully loaded |
30.55 lb (13.75 kg)
fully loaded |
| Memory and processor |
|
|
|
| Fabric module: |
Motorola PowerPC @ 200 MHz, 12 MB flash, 32 MB SDRAM |
Motorola PowerPC @ 200 MHz, 12 MB flash, 32 MB SDRAM |
Motorola PowerPC @ 200 MHz, 12 MB flash, 32 MB SDRAM |
| Module |
|
ARM9 @ 66 MHz, 128 KB flash, 128 KB SRAM, 18 MB RDRAM Packet buffer size: 36 MB |
ARM9 @ 66 MHz, 128 KB flash, 128 KB SRAM, 18 MB RDRAM Packet buffer size: 36 MB |
|
Dual Flash |
Dual Flash |
Dual Flash |
| Packet buffer size: |
36 MB |
|
|
| Performance |
|
|
|
| Latency: |
< 6 µs (FIFO) |
< 6 µs (FIFO) |
< 6 µs (FIFO) |
| Throughput: |
up to 24 million pps |
up to 24 million pps |
up to 48 million pps |
| Switch fabric speed: |
38.4 Gbps |
38.4 Gbps |
76.8 Gbps |
| Address table size: |
10,000 entries |
10,000 entries |
10,000 entries |
| Environment |
|
|
|
| Operating temperature: |
32 °F to 104 °F (0 °C to 40 °C) |
32 °F to 104 °F (0 °C to 40 °C) |
32 °F to 104 °F (0 °C to 40 °C) |
| Operating relative humidity: |
15 % to 95 % at 104 °F (40 °C), noncondensing |
15 % to 95 % at 104 °F (40 °C), noncondensing |
15 % to 95 % at 104 °F (40 °C), noncondensing |
| Non-operating/storage temperature: |
-40 °F to 158 °F (-40 °C to 70 °C) |
-40 °F to 158 °F (-40 °C to 70 °C) |
-40 °F to 158 °F (-40 °C to 70 °C) |
| Non-operating/storage relative humidty: |
15 % to 95 % at 149 °F (65 °C), noncondensing |
15 % to 95 % at 149 °F (65 °C), noncondensing |
15 % to 95 % at 149 °F (65 °C), noncondensing |
| Altitude: |
up to 15,091 ft (4.6 km) |
up to 15,091 ft (4.6 km) |
up to 15,091 ft (4.6 km) |
| Electrical characteristics |
|
|
|
| Maximum BTUs: |
2,152 BTU/hr |
2,152 BTU/hr |
2,152 BTU/hr |
| Voltage: |
100-127 VAC/200-240 VAC |
100-127 VAC/200-240 VAC |
100-127 VAC/200-240 VAC |
| Current: |
8.2 A /3.8 A |
8.2 A /3.8 A |
8.2 A /3.8 A |
| Power: |
630 W |
630 W |
630 W |
| Frequency: |
50/60 Hz |
50/60 Hz |
50/60 Hz |
|
|
» Return to top
|
| Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only |
 |
| cUL (CSA 950); EN 60950/IEC 60950; NOM-019-SCFI-1994; UL 1950 3rd edition |
 |
| FCC Class A; EN 55022/CISPR-22 Class A; VCCI Class A |
 |
| EN: 55024/CISPR 24 |
| ESD: IEC 61000-4-2, 4 kV CD, 8 kV AD |
| Radiated: IEC 61000-4-3, 3V/m |
| EFT/Burst: IEC 6100-4-4, 1.0 kV (power line), 0.5 kV (signal line) |
| Surge: IEC 61000-4-5, 1 kV/2 kV AC |
| Conducted: IEC 61000-4-6, 3V |
| Power frequency magnetic field: IEC 61000-4-8, 1A/m, 50 or 60 Hz |
| Voltage dips and interruptions: IEC 61000-4-11, >95% reduction, 0.5 period; 30% reduction, 25 periods |
| Harmonics: EN 61000-3-2/IEC 61000-3-2 |
| Flicker: EN 61000-3-3/IEC 61000-3-3 |
 |
| ProCurve Manager (included); ProCurve Manager Plus; command-line interface; Web browser; configuration menu; out-of-band management (serial RS-232C) |
 |
| RFC 783 TFTP |
| RFC 1542 BootP |
| RFC 768 UDP |
| RFC 793 TCP |
| RFC 2030 Simple Network Time Protocol |
| DHCP Relay |
| RFC 2453 RIPv2 |
| IGMPv3 |
| IEEE 802.1w Rapid Convergence Spanning Tree |
| IEEE 802.3ad Link Aggregation Control Protocol |
| ANSI/TIA-1057 LLDP Media Endpoint Discovery (MED) |
| RFC 2597 DiffServ Expedited Forwarding (EF) |
| RFC 1492 TACACS+ |
| RFC 2866 RADIUS accounting |
| Secure Sockets Layer (SSL) |
| 802.3af Power over Ethernet |
| IEEE 802.1Q GVRP |
| SNMPv1/v2c/v3 |
| RFC 1493 Bridge MIB |
| RFC 1213 MIB II |
| RFC 2737 Entity MIB |
| RFC 2665 Ethernet MIB |
| RFC 1724 RIPv2 MIB |
| XRMON |
| RFC 2021 RMON probe configuration (RMON v2) |
| RFC 2613 SMON |
| RFC 1850 OSPF MIB |
| RFC 2620 RADIUS Accounting MIB |
|
|
| RFC 951 BootP |
| RFC 854 Telnet |
| RFC 792 ICMP |
| RFC 826 ARP |
| IEEE 802.3x Flow Control |
| RFC 3376 IGMPv1/v2/v3 |
| RFC 2328 OSPFv2 (includes route authentication) |
| IEEE 802.1D Spanning Tree |
| IEEE 802.1s Multiple Spanning Trees |
| IEEE 802.1AB Link Layer Discovery Protocol |
| RFC 2474 DiffServ Precedence |
| RFC 2598 DiffServ Assured Forwarding (AF) |
| RFC 2138 RADIUS |
| SSHv1/SSHv2 Secure Shell |
| IEEE 802.1X Network Login |
| IEEE 802.1Q VLAN tagging |
| IEEE 802.1p Priority |
| HTML and telnet management |
| PIM Dense |
| RFC 2096 IP Forwarding Table MIB |
| RFC 2863 Evolution of Interface |
| RFC 1058 RIP |
| RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events) |
| sFlow |
| RFC 2668 802.3 MAU MIB |
| RFC 2674 802.1p and IEEE 802.1Q Bridge MIB |
| RFC 2618 RADIUS Client MIB |
| RFC 3046 DHCP Relay Agent Information Option |
|
|
 |
|
 |
» Return to top |
 |
 |
 |
|
|