|
ProCurve Switch 2900-24G
(J9049A) |
|
| Ports |
20 RJ-45 10/100/1000 ports
(IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-T, IEEE 802.3ab Type 1000Base-T)
2 CX4 10-GbE ports
2 X2 ports
1 RS-232C DB-9 console port
4 Dual Personality Ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)
|
44 RJ-45 10/100/1000 ports
(IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-T, IEEE 802.3ab Type 1000Base-T)
2 CX4 10-GbE ports
2 X2 ports
1 RS-232C DB-9 console port
4 Dual Personality Ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)
|
| Physical characteristics |
|
|
| Dimensions: |
15.43 x 17.44 x 1.73 in.
(39.2 x 44.3 x 4.4 cm)
1U height |
16.93 x 17.44 x 1.73 in.
(43.0 x 44.3 x 4.4 cm)
1U height |
| Weight: |
14.11 lb (6.3 kg) |
15.43 lb (7 kg) |
| Memory and processor |
|
|
| Processor type and speed: |
Freescale PowerPC 8540, 667 MHz |
Freescale PowerPC 8540, 667 MHz |
| Packet buffer size: |
13.5 MB |
22.5 MB |
| Flash capacity: |
4 MB |
4 MB |
| Performance |
|
|
| 1000 MB: |
< 3.7 µs (FIFO 64-byte packets) |
< 3.7 µs (FIFO 64-byte packets) |
| 10 Gb: |
< 2.1 µs (FIFO 64-byte packets) |
< 2.1 µs (FIFO 64-byte packets) |
| Throughput: |
up to 74 million pps (64-byte packets) |
up to 110 million pps (-byte packets) |
| Routing/switching capacity: |
101 Gbps |
148 Gbps |
| Switching capacity: |
115 Gbps |
173 Gbps |
| Environment |
|
|
| Operating temperature: |
32 °F to 131 °F (0 °C to 55 °C) |
32 °F to 131 °F (0 °C to 55 °C) |
| Operating relative humidity: |
15 % to 95 % at 104 °F (40 °C), noncondensing |
15 % to 95 % at 104 °F (40 °C), noncondensing |
| Non-operating/storage temperature: |
-40 °F to 158 °F (-40 °C to 70 °C) |
-40 °F to 158 °F (-40 °C to 70 °C) |
| Non-operating/storage relative humidty: |
15 % to 90 % at 149 °F (65 °C), noncondensing |
15 % to 90 % at 149 °F (65 °C), noncondensing |
| Altitude: |
up to 15091 ft (4.6 km) |
up to 15091 ft (4.6 km) |
| Acoustic: |
DIN 45635T.19 per ISO 7779 49.3 dB |
DIN 45635T.19 per ISO 7779 52 dB |
| Electrical characteristics |
|
|
| Description: |
The switch automatically adjusts to any voltage between 100-127 and 200-240 volts and either 50 or 60 Hz |
The switch automatically adjusts to any voltage between 100-127 and 200-240 volts and either 50 or 60 Hz |
| Maximum heat dissipation: |
683 BTU/hr ( 720.57 kJ/hr ) |
683 BTU/hr ( 720.57 kJ/hr ) |
| Voltage: |
100-127 VAC/200-240 VAC |
100-127 VAC/200-240 VAC |
| Current: |
4.0 A /2.0 A |
4.0 A /2.0 A |
| Power: |
200 W |
200 W |
| Frequency: |
50/60 Hz |
50/60 Hz |
| Mounting |
|
|
|
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only. |
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only. |
| Safety |
|
|
|
CSA 22.2 No. 60950; UL 60950; IEC60950; EN60950 |
CSA 22.2 No. 60950; UL 60950; IEC60950; EN60950 |